Warning message

Member access has been temporarily disabled. Please try again later.
The AVE Houston website is undergoing a major upgrade that began Friday, October 11th at 5:00 PM PDT. The new upgraded site will be available no later than Monday, October 21st. Until that time, the current site will be visible but logins are disabled.

 

Disclaimer: This material is being kept online for historical purposes. Though accurate at the time of publication, it is no longer being updated. The page may contain broken links or outdated information, and parts may not function in current web browsers. Visit https://espo.nasa.gov for information about our current projects.

 

Real-time aerosol mass spectrometry with millisecond resolution

Kimmel, J. R., D. K. Farmer, M. J. Cubison, D. Sueper, C. Tanner, E. Nemitz, D. Worsnop, M. Gonin, and J. Jimenez-Palacios (2011), Real-time aerosol mass spectrometry with millisecond resolution, International Journal of Mass Spectrometry, 303, 15-26, doi:10.1016/j.ijms.2010.12.004.
Abstract: 

The time-of-flight aerosol mass spectrometer (ToF-AMS) determines particle size by measuring velocity after expansion into vacuum and analyzes chemical composition by thermal vaporization and electron ionization mass spectrometry (MS). Monitoring certain dynamic processes requires the ability to track changes in aerosol chemistry and size with sub-second time resolution. We demonstrate a new ToFAMS data acquisition mode capable of collecting high-resolution aerosol mass spectra at rates exceeding

kHz. Coupled aerosol size and MS measurements can be made at approximately 20 Hz. These rates are about 1/10 of the physically meaningful limits imposed by the ToF-AMS detection processes. The fundamentals of the time-of-flight MS (TOFMS) data acquisition system are described and characterized with a simple algebraic model. Derived expressions show how improvements in data acquisition and computer hardware will translate into rates approaching the physical limits. Conclusions regarding limits of performance can be extended to other TOFMS that use analog signal detection in a high-speed application outside of aerosol science. The high-speed acquisition mode of the ToF-AMS enables speciated aerosol eddy covariance flux measurements, which demand precise, 10-Hz synchronization of the MS with a sonic anemometer. Flux data acquired over a forest during the BEARPEX-1 campaign are presented as an example of this new technique. For aircraft measurements, faster acquisition translates to higher spatial resolution, which is demonstrated with data from the recent NASA ARCTAS field campaign in Alaska. Finally, the fast acquisition mode is used to measure the rapid fluctuations in particle emissions of a controlled biomass burn during from the FLAME-2 experiment. To our knowledge this is currently the fastest system for acquisition of chemically resolved aerosol data.

PDF of Publication: 
Download from publisher's website.
Research Program: 
Tropospheric Composition Program (TCP)
Mission: 
ARCTAS