24 1001 Toohey, Darin; Thornton, Brett University of Colorado-Boulder ClO mixing ratio in ppt from HOT (Halogen Oxides in the Troposphere) instrument SOLVE 1 1 1999 12 07 2002 08 07 0 time (UT seconds) from 00 hours on launch date 2 1.0E-2 1.0E-2 999999 999999 ClO mixing ratio (ppt) ClO 1-sigma precision (ppt) 0 8 These are revised (August 2002) ClO values for SOLVE, reflecting all post-mission instrument calibrations and tests. Times are the midpoint of the measurement period (approximately 20 minutes). Faster data is available with correspondingly larger uncertainties. 1-sigma precision information is provided for each data point. Contact Darin Toohey or Brett Thornton for further information. UT ClO precision 38550 2890 1429 39750 4377 2227 40950 1869 518 42150 -4 492 43350 1446 521 44733.5 1955 1621 46435.57 999999 999999 48219.57 999999 999999 49422.5 -631 499 50622.5 350 442 51822.5 827 446 53022.5 643 449 54222.5 687 465 55422.5 1047 472 56622.5 1488 577 57822.5 537 509 59022.5 583 557 60222.5 25 609 61422.5 562 691 62622.5 855 717 63822.5 -917 716 65022.5 718 691