Synonyms: 
C-130 Hercules
C-130H Hercules
C-130H
NASA C-130H - WFF
C-130 - WFF
Associated content: 
Sub-categories: 

BroadBand Radiometers

The Broadband Radiometers (BBR) consist of modified Kipp & Zonen CM-22 pyranometers (to measure solar irradiance) and CG-4 pyrgeometers (to measure IR irradiance) (see http://www.kippzonen.com/). The modifications to make these instruments more suitable for aircraft use include new instrument housings and amplification of the signal at the sensor. The instruments are run in current-loop mode to minimize the effects of noise in long signal cables. The housing is sealed and evacuated to prevent condensation or freezing inside the instrument. Each BBR has the following properties: Field-of-view: Hemispheric Temperature Range: -65C to +80C Estimated Accuracy: 3-5% Data Rate: 1Hz

Instrument Type: 
Point(s) of Contact: 

Chemical Ionization Mass Spectrometer

The single mass analyzer CIMS (S-CIMS) was developed for use on NASA’s ER-2 aircraft. Its first measurements were made in 2000 (SOLVE, see photo). Subsequently, it has flown on the NASA DC-8 aircraft for INTEX-NA, DICE, TC4, ARCTAS, ATom, KORUS, FIREX, as well as on the NCAR C-130 during MILAGRO/INTEX-B. HNO3 is measured by selective ion chemical ionization via the fluoride transfer reaction: CF3O- + HNO3 → HF • NO3- + CF2O In addition to its fast reaction rate with HNO3, CF3O- can be used to measure additional acids and nitrates as well as SO2 [Amelynck et al., 2000; Crounse et al., 2006; Huey et al., 1996]. We have further identified CF3O- chemistry as useful for the measurement of less acidic species via clustering reactions [Crounse et al., 2006; Paulot et al., 2009a; Paulot et al., 2009b; St. Clair et al., 2010]: CF3O- + HX → CF3O- • HX where, e.g., HX = HCN, H2O2, CH3OOH, CH3C(O)OOH (PAA) The mass analyzer of the S-CIMS instrument was first upgraded from a quadrupole to a unit-mass resolution time-of-flight (ToF) analyzer. In 2023, the mass filter was again upgraded to an 1m flight path (~5000 deltaM/M).  The ToF admits the sample ion beam to the ion extractor, where a pulse of high voltage orthogonally deflects and accelerates the ions into the reflectron, which in turn redirects the ions toward the multichannel plate detector. Ions in the ToF follow a V-shaped from the extractor to detector, separating by mass as the smaller ions are accelerated to greater velocities by the high voltage pulse. The detector collects the ions as a function of time following each extractor pulse. The rapid-scan collection of the ToF guarantees a high temporal resolution (1 Hz or faster) and simultaneous data products from the S-CIMS instrument for all mass channels [Drewnick et al., 2005]. We have flown a tandem CIMS (TCIMS) instrument in addition to the SCIMS since INTEX-B (2006). The T-CIMS provides parent-daughter mass analysis, enabling measurement of compounds precluded from quantification by the S-CIMS due to mass interferences (e.g. MHP) or the presence of isobaric compounds (e.g. isoprene oxidation products) [Paulot et al., 2009b; St. Clair et al., 2010]. Calibrations of both CIMS instruments are performed in flight using isotopically-labeled reagents evolved from a gas cylinders or from a thermally-stabilized permeation tube oven [Washenfelder et al., 2003]. By using an isotopically labeled standard, the product ion signals are distinct from the natural analyte and calibration can be performed at any time without adversely affecting the ambient measurement.

Instrument Type: 
Point(s) of Contact: 

Continuous Flow Streamwise Thermal Gradient CCN Counter

Developed by Droplet Measurement Technologies, the CFSTGC is based on a concept by Roberts and Nenes [2005]. The instrument counts the fraction of aerosol particles that become droplets when exposed to a given water vapor supersaturation (RH > 100%).

As with all CCN counters, a temperature gradient is applied to produce a supersaturation of water vapor. However, the mechanism for generating supersaturation is not the same for all CCN counters. For example, for continuous flow parallel plate diffusion chambers, the temperature gradient is perpendicular to the flow, and supersaturation is a result of the nonlinear dependence of vapor pressure upon temperature. The same mechanism applies for static diffusion cloud chambers, where there is no flow at all.

However, as the name implies, for the Continuous Flow Streamwise Thermal Gradient CCN Counter, the temperature gradient is in the streamwise direction (maintained by thermoelectric coolers). In this case, supersaturation results as a consequence of the greater rate of mass transfer over heat transfer.

With laminar flow, heat and water vapor are transferred to the centerline of the column from the walls only by diffusion.

Since molecular diffusivity is greater than thermal diffusivity, the distance downstream that a water molecule travels before reaching the centerline is less than the distance the heat travels downstream before reaching the centerline. If you pick a point at the centerline, the heat originated from a greater distance upstream than the water vapor.

There are four facts that are necessary to explain how supersaturation is generated within the CFSTGC:

1) Assuming that the inner surface of the column is saturated with water vapor at all points, since the temperature is greater at point B than at point A, the water vapor partial pressure is also greater at point B than at point A.

2) The actual partial pressure of water vapor at point C is equal to the partial pressure of water vapor at point B.

3) However, since the temperature at point C is the same as at point A, the equilibrium water vapor pressure at point C is equal to the water vapor partial pressure at point A.

4) The saturation ratio is the ratio between the actual partial pressure of water vapor and the equilibrium vapor pressure. This is equivalent to the partial pressure at point B divided by the partial pressure at point A, which is always greater than one. Thus supersaturation is generated through a dynamic equilibrium.

Instrument Type: 
Measurements: 
Aircraft: 
Balloon, P-3 Orion - WFF, C-130H - WFF, DC-8 - AFRC, HU-25 Falcon - LaRC
Point(s) of Contact: 

Airborne Earth Science Microwave Imaging Radiometer

The Airborne Earth Science Microwave Imaging Radiometer (AESMIR) is a passive microwave airborne imager covering the 6-100 GHz bands that are essential for observing key Earth System elements such as precipitation, snow, soil moisture, ocean winds, sea ice, sea surface temperature, vegetation, etc.

AESMIR’s channels are configured to enable it to simulate various channels on multiple satellite radiometers, including AMSR-E, SSMI, SSMIS, AMSU, ATMS, TMI, GMI, ATMS, & MIS. Programmable scan modes include conical and cross-track scanning. As such, AESMIR can serve as an inter-satellite calibration tool for constellation missions (e.g., GPM) as well as for long-term multi-satellite data series (Climate Data Records).

The most unique/cutting edge feature of the instrument is its coverage of key water cycle microwave bands in a single mechanical package—making efficient & cost-effective use of limited space on research aircraft, and maximizing the possibilities for co-flying with other instruments to provide synergistic science. State-of-the-art calibration, fully-polarimetric (4-Stokes) observations, and the ability to accommodate large/heavy sensors (up to 300 kg) are other features of AESMIR. AESMIR currently flies on the NASA P-3 aircraft.

With these capabilities, AESMIR is an Earth Science facility for new microwave remote sensing discovery, pre-launch algorithm development, and post-launch Calibration/Validation activities, as well as serving as a technology risk reduction testbed for upcoming spaceborne radiometers. In the latter role, AESMIR is already supporting the GPM, Aquarius, and SMAP missions.

Instrument Type: 
Point(s) of Contact: 

Airborne Topographic Mapper

The Airborne Topographic Mapper (ATM) is a scanning LIDAR developed and used by NASA for observing the Earth's topography for several scientific applications, foremost of which is the measurement of changing arctic and antarctic icecaps and glaciers. It typically flies on aircraft at an altitude between 400 and 800 meters above ground level, and measures topography to an accuracy of ten to twenty centimeters by incorporating measurements from GPS (global positioning system) receivers and inertial navigation system (INS) attitude sensors.

The ATM instruments are based at NASA's Wallops Flight Facility (WFF) in Virginia. They commonly fly aboard the NASA P3-B based at WFF and have flown aboard other P-3 aircraft, the NASA DC-8, several twin-otters (DHC-6), and a C-130; they can fly on most Twin Otter/King Air-class aircraft. The ATM has flown surveys in Greenland nearly every year since 1993. Other uses have included measurement of sea ice, verification of satellite radar and laser altimeters, and measurement of sea-surface elevation and ocean wave characteristics. The altimeter often flies in conjunction with a variety of other instruments. The ATM has been participating in NASA's Operation IceBridge since 2009.

Instrument Type: 
Measurements: 
Point(s) of Contact: 
William Krabill (Prev PI)

Pages

Subscribe to RSS - C-130H - WFF