Disclaimer: This material is being kept online for historical purposes. Though accurate at the time of publication, it is no longer being updated. The page may contain broken links or outdated information, and parts may not function in current web browsers. Visit https://espo.nasa.gov for information about our current projects.

 

Impact of using a new ultraviolet ozone absorption cross-section dataset on OMI...

Bak, J., X. Liu, M. Birk, G. Wagner, I. E. Gordon, and K. Chance (2020), Impact of using a new ultraviolet ozone absorption cross-section dataset on OMI ozone profile retrievals, Atmos. Meas. Tech., 13, 5845-5854, doi:10.5194/amt-13-5845-2020.
Abstract: 

We evaluate different sets of high-resolution ozone absorption cross-section data for use in atmospheric ozone profile measurements in the Hartley and Huggins bands with a particular focus on BDM 1995 (Daumont et al. 1992; Brion et al., 1993; Malicet et al., 1995), currently used in our retrievals, and a new laboratory dataset by Birk and Wagner (2018) (BW). The BDM cross-section data have been recommended to use for retrieval of ozone profiles using spaceborne nadir-viewing backscattered ultraviolet (BUV) measurements since its improved performance was demonstrated against other cross-sections including Bass and Paur (1985) (BP) and those of Serdyuchenko et al. (2014) and Gorshelev et al. (2014) (SER) by the “Absorption Cross-Sections of Ozone” (ACSO) activity. The BW laboratory data were recently measured within the framework of the European Space Agency (ESA) project SEOMIAS (Scientific Exploitation of Operational Missions – Improved Atmospheric Spectroscopy Databases) to provide an advanced absorption cross-section database. The BW crosssections are made from measurements at more temperatures and in a wider temperature range than BDM, especially for low temperatures. Relative differences of cross-sections between BW and BDM range from ∼ 2 % at shorter UV wavelengths to ∼ 5 % at longer UV wavelengths at warm temperatures. Furthermore, these differences dynamically increase by up to ±40 % at cold temperatures due to no BDM measurements having been made below 218 K. We evaluate the impact of using different cross-sections on ozone profile retrievals from Ozone Monitoring Instrument (OMI) measurements. Correspondingly, this impact leads to significant differences in individual ozone retrievals by up to 50 % in the tropopause where the coldest atmospheric temperatures are observed. Bottom atmospheric layers illustrate the significant change of the retrieved ozone values, with differences of 20 % in low latitudes, which is not the case in high latitudes because the ozone retrievals are mainly controlled by a priori ozone information in high latitudes due to less photon penetration down to the lower troposphere. Validation with ozonesonde observations demonstrates that BW and BDM retrievals show altitude-dependent bias oscillations of similar magnitude relative to ozonesonde measurements, much smaller than those of both BP and SER retrievals. However, compared to BDM, BW retrievals show significant reduction in standard deviation, by up to 15 %, especially at the coldest atmospheric temperatures. Such improvement is achieved mainly by the better characterization of the temperature dependence of ozone absorption.

PDF of Publication: 
Download from publisher's website.
Research Program: 
Atmospheric Composition
Mission: 
Aura- OMI
TEMPO