Disclaimer: This material is being kept online for historical purposes. Though accurate at the time of publication, it is no longer being updated. The page may contain broken links or outdated information, and parts may not function in current web browsers. Visit https://espo.nasa.gov for information about our current projects.

 

Associated content: 

Small Ice Detector

Instrument Type: 
Aircraft: 
C-130H - WFF, DC-8 - AFRC, Gulfstream V - NSF, WB-57 - JSC
Point(s) of Contact: 

Fast In-situ Stratospheric Hygrometer

The Fast In situ Stratospheric Hygrometer (FISH), developed at the Forschungszentrum Jülich (Germany), is based on the Lyman-a photofragment fluorescence technique. Details of the instrument and the calibration procedure are described in Zöger et al. [1999]. FISH has been used in several campaigns both from balloon and aircraft and compared with a large number of other hygrometers [Kley et al., 2000].

FISH consists of a closed, vacuum-tight fluorescence cell, a Lyman-a radiation source, a PMT in photon-counting mode, detectors to monitor the VUV radiation output of the Lyman-a lamp, and a mirror drive that controls the measuring cycle (see diagram): determination of the fluorescence and background count rate and of the lamp intensity. With a measurement frequency of 1 Hz, the noise equivalent mixing ratio at 3 ppmv is 0.2-0.15 ppmv, and the detection limit is 0.18-0.13 ppmv.

FISH is calibrated between flights in the laboratory using a calibration bench under realistic conditions, that is varying the H2O mixing ratio of the test air from a few ppmv to several hundred ppmv and the pressure from 1000 to 10 hPa. A frost point hygrometer is used as a reference instrument. The overall accuracy of FISH measurements is 5-6 %.

Measurements: 
Aircraft: 
Point(s) of Contact: 

High Volume Precipitation Spectrometer

SPEC previously built the Version 1 and Version 2 HVPS probes that have now been discontinued due to obsolete parts and significant advances in technology. The HVPS-3 uses the same 128-photodiode array and electronics that are used in the 2D-S and 2D-128 probes. The optics are configured for 150 micron pixel resolution, resulting in a maximum field of view of 1.92 cm (i.e., particles up to 1.92 cm are completely imaged, although even larger particles can be sized in the direction of flight).

Sample volume of the HVPS-3 is 400 L s-1 at 100 m s-1. The 2D-S or 2D-128 and HVPS make an excellent pair of probes that completely image particles from 10 microns to 1.92 cm.

Point(s) of Contact: 

Cloud Droplet Probe

The Cloud Droplet Probe (CDP), manufactured by Droplet Measurement Technologies, measures the concentration and size distribution of cloud droplets in the size range from 2-50 µm. The instrument counts and sizes individual droplets by detecting pulses of light scattered from a laser beam in the near-forward direction, using a sample area of 0.24 mm2 or a sample rate of 48 cm3 at a flight speed of 200 m/s. The probe is mounted in an underwing canister and is designed to operate at up to 200 m/s; the G-V often exceeds this flight speed, but usually not in penetrations of clouds containing cloud droplets. Droplet sizes are accumulated in 30 bins with variable sizes, as specied in the header of the netCDF data files. Measurements are usually provided at a rate of 1 Hz in the standard data files but can be made available at 10 Hz in special high-rate processing. The instrument is similar to, and might be considered a high-speed replacement for, the Forward Scattering Spectrometer Probe. At high droplet concentration (> 500 cm-3), coincidence losses have been observed with this probe, and these are especially serious at G-V flight speeds. The probe is designed for cloud droplets, and its response to ice crystals is not intended to be quantitative; measurements in ice clouds should not be used except as qualitative indications of cloud.

Instrument Type: 
Aircraft: 
Point(s) of Contact: 

Unmanned Aerial System Laser Hygrometer

ULH measures water vapor at high accuracy in the upper troposphere and lower stratosphere to meet the following science objectives:

1. validation and scientific collaboration with NASA earth-monitoring satellite missions, principally the Aura satellite, http://aura.gsfc.nasa.gov/

2. observations of stratospheric trace gases in the upper troposphere and lower stratosphere from the mid-latitudes into the tropics,

3. sampling of polar stratospheric air and the break-up fragments of the air that move into the mid-latitudes, The ULH flights on Global Hawk will advance the state of the art technologically with remote command and control. ULH will provide real-time in-situ stratospheric water vapor measurements from Global Hawk. Additionally, ULH will make continuous measurements during long-duration flights up to 33 hours, which would be impossible with manned aircraft.

The advantages of ULH over other hygrometers are:

• Small and lightweight instrument package,
• No outgassing (achieved by mounting the open-path optical cell in the free air stream),
• Fast time response measurements in and out of clouds, without contamination,
• Accurate with a low detection limit <1 ppmv.

Measurements: 
Point(s) of Contact: 

Single Particle Soot Photometer (NOAA)

The SP2 is a laser-induced incandescence instrument primarily used for measuring the refractory BC  (rBC) mass content of individual accumulation-mode aerosol particles. It is able to provide this data product independently of the total particle morphology and mixing state, and thus delivers detailed information not only about BC loadings, but also size distributions, even in exceptionally clean air. The instrument can also provide the optical size of individual particles containing rBC, and identify the presence of materials associated with the BC fraction (i.e. identify the rBC’s mixing state). Since its introduction in 2003, the SP2 has been substantially improved, and now can be considered a highly competent instrument for assessing BC loadings and mixing state in situ.  NOAA deploys multiple SP2s with different designs: the first was built for the WB-57F research aircraft. Two others are rack-mounted units customized at NOAA; one of the rack mounted units can be humidified, and has been deployed with a paired dry rack-mounted SP2 as the "Humidified-Dual SP2" (HD-SP2). The rack mounted units are suitable for in-cabin operations.

Instrument Type: 
Measurements: 
Point(s) of Contact: 

Video Ice Particle Sampler

The VIPS is an electro-optical instrument used to collect and record a continuous sample of cloud particles down to 5 um. Particles are collected continuously on a looped belt coated with silicone oil. The portion of the belt exposed to the airstream is imaged by two very high resolution charged coupled device (CCD) shuttered video cameras with different resolutions. The resulting imagery is available for real-time, in-flight evaluation of cloud conditions and for post-flight habit classification and spectra analysis.

The VIPS system is composed of two parts: (1) an electro-optical collection and imaging unit mounted in a standard particle measurement system (PMS) can, and (2) data acquisition and recording components. Aperture width of the collection subassembly is adjustable for varying flight conditions. The CCD imaging cameras are coupled with inline, high detail video enhancers. Particle imagery is recorded continuously at 30 Hz on high-resolution Hi-8 VCRs. Images are also captured at 1 Hz, digitized in real-time and recorded on an Apple PowerPC.

Instrument Type: 
Measurements: 
Aircraft: 
Point(s) of Contact: 

Particle Analysis By Laser Mass Spectrometry

The NOAA PALMS instrument measures single-particle aerosol composition using UV laser ablation to generate ions that are analyzed with a time-of-flight mass spectrometer.  The PALMS size range is approximately 150 to >3000 nm and encompasses most of the accumulation and coarse mode aerosol volume. Individual aerosol particles are classified into compositional classes.  The size-dependent composition data is combined with aerosol counting instruments from Aerosol Microphysical Properties (AMP), the Langley Aerosol Research Group Experiment (LARGE), and other groups to generate quantitative, composition-resolved aerosol concentrations.  Background tropospheric concentrations of climate-relevant aerosol including mineral dust, sea salt, and biomass burning particles are the primary foci for the ATom campaigns.  PALMS also provides a variety of compositional tracers to identify aerosol sources, probe mixing state, track particle aging, and investigate convective transport and cloud processing.

*_Standard data products_**: *

Particle type number fractions: sulfate/organic/nitrate mixtures, biomass burning, EC, sea salt, mineral dust, meteoric, alkali salts, heavy fuel combustion, and other. Sampling times range from 1-5 mins.

*_Advanced data products_**:*

Number, surface area, volume, and mass concentrations of the above particle types. Total sulfate and organic mass concentrations. Relative and absolute abundance of various chemical markers and aerosol sub-components: methanesulfonic acid, sulfate acidity, organic oxidation level, iodine, bromine, organosulfates, pyridine, and other species.

Instrument Type: 
Point(s) of Contact: 

Nuclei-Mode Aerosol Size Spectrometer

The nucleation-mode aerosol size spectrometer (NMASS) measures the concentration of particles as a function of diameter from approximately 4 to 60 nm. A sample flow is continuously extracted from the free stream using a decelerating inlet and is transported to the NMASS. Within the instrument, the sample flow is carried to 5 parallel condensation nucleus counters (CNCs) as shown in Fig. 1. Each CNC is tuned to measure the cumulative concentration of particles larger than certain diameter. The minimum detectable diameters for the 5 CNCs are 4.0, 7.5, 15, 30 and 55 nm, respectively. An inversion algorithm is applied to recover a continuous size distribution in the 4 to 60 nm diameter range.

The NMASS has been proven particularly useful in measurements of nucleation-mode size distribution in environments where concentrations are relatively high and fast instrumental response is required. The instrument has made valuable measurements vicinity of cirrus clouds in the upper troposphere and lower stratosphere (WAM), in the near-field exhaust of flying aircraft (SULFUR 6), in newly created rocket plumes (ACCENT), and in the plumes of coal-fired power plants (SOS ’99). The instrument has flown on 3 different aircraft and operated effectively at altitudes from 50 m to 19 km and ambient temperatures from 35 to -80ºC.

Accuracy. The instrument is calibrated using condensationally generated particles that are singly charged and classified by differential electrical mobility. Absolute counting efficiencies are determined by comparison with an electrometer. Monte carlo simulations of the propagation of uncertainties through the numerical inversion algorithm and comparison with established laboratory techniques are used to establish accuracies for particular size distributions, and may vary for different particle size distributions. A study of uncertainties in aircraft plume measurements demonstrated a combined uncertainty (accuracy and precision) of 38%, 36% and 38% for number, surface and volume, respectively.

Precision. The precision is controlled by particle counting statistics for each channel. If better precision is desired, it is necessary only to accumulate over longer time intervals.

Response Time: Data are recorded with 10 Hz resolution, and the instrument has demonstrated response times of this speed in airborne sampling. However the effective response time depends upon the precision required to detect the change in question. Small changes may require longer times to detect. Plume measurements with high concentrations of nucleation-mode particles may be processed at 10 Hz.

Specifications: Weight is approximately 96 lbs, including an external pump. External dimensions are approximately 15”x16”x32”. Power consumption is 350 W at 28 VDC, including the pump.

Instrument Type: 
Aircraft: 
Point(s) of Contact: 
Michael Reeves (Prev PI)

JPL Laser Hygrometer

The JPL Laser Hygrometer (JLH) is an autonomous spectrometer to measure atmospheric water vapor from airborne platforms. It is designed for high-altitude scientific flights of the NASA ER-2 aircraft to monitor upper tropospheric (UT) and lower stratospheric (LS) water vapor for climate studies, atmospheric chemistry, and satellite validation. JLH will participate in the NASA SEAC4RS field mission this year. The light source for JLH is a near-infrared distributed feedback (DFB) tunable diode laser that scans across a strong water vapor vibrational-rotational combination band absorption line in the 1.37 micrometer band. Both laser and detector are temperature‐stabilized on a thermoelectrically-cooled aluminum mount inside an evacuated metal housing. A long optical path is folded within a Herriott Cell for sensitivity to water vapor in the UT and LS. A Herriott cell is an off-axis multipass cell using two spherical mirrors [Altmann et al., 1981; Herriott et al., 1964]. The laser beam enters the Herriott cell through a hole in the mirror that is closest to the laser. The laser beam traverses many passes of the Herriott cell and then returns through the same mirror hole to impinge on a detector.

Instrument Type: 
Measurements: 
Point(s) of Contact: 

Pages